Exceptionally robust with 99.5% accuracy

Accurate capacitive fuel-level sensors lie at the heart of effective fuel monitoring, empowering fleet operators to monitor fuel consumption, mileage in km per litre and precise fuel levels at any time. OMNICOMM's capacitive sensors are highly accurate and reliable, with a long work-life, and require no technical maintenance.

  • 99.5% accuracy – to provide precise meaningful data
  • IP69k ingress protection rating – to reliably perform even in extreme conditions of moist, dust, vibration and in a wide range of temperatures
  • 1+ million vehicles equipped in 110 countries
  • Fully guaranteed with a 5 years warranty: warranty claims rate of just 0.009% since 2017
  • Integration with 3rd party trackers & fleet management solutions
  • Off-the shelf size from 700 to 3.000 mm. Easily adjustable to fit the tanks of most sizes

Installed in over 1 million vehicles worldwide

Trusted by 100s of companies to monitor fuel and cut costs

Omnicomm LLS 5

OMNICOMM LLS 5 uses OMNICOMM's unique Fuelscan® technology to guarantee unprecedented accuracy of 99.5% in all conditions. Using measurements from an additional probe in the sensor to compare filled fuel characteristics with the fuel used for calibration and calculate measurements accordingly, this sensor sets a new industry standard and is twice as accurate as regular capacitive fuel-level sensors.


Omnicomm LLS 5
Error in measurement, % ± 0,5          
Output RS-232, RS-485
Power supply voltage, V 7...75          
Ingress protection rating IP69k
Dielectric strength of galvanic isolation, min, V 2500
Operating temperature, C  - 60 ... +85
Temperature measuring range, C - 40 ... + 80
Resolution, bit 12
Output range of readings corresponding to the maximum      
value of measured level
1...4095
Output range of readings corresponding to the minimum      
value of measured level
0...4094

Omnicomm LLS-EX 5

OMNICOMM LLS-Ex 5 is the explosion-proof version of OMNICOMM LLS 5, using OMNICOMM's auto-adjusting Fuelscan® technology to guarantee unprecedented accuracy of 99.5% in all conditions. OMNICOMM LLS-Ex 5 is designed for use in equipment operating in potentially hazardous areas. It can be installed in mobile and stationary fuel tanks and storages up to 6 meters in height. 


Omnicomm LLS-EX 5
Error in measurement, % ± 0,5          
Output RS-232, RS-485
Power supply voltage, V 7...60(through BIS-MX)          
Ingress protection rating IP69k
Dielectric strength of galvanic isolation, min, V 7000
Operating temperature, C  - 60 ... +85
Temperature measuring range, C - 40 ... + 80
Resolution, bit 12
Output range of readings corresponding to the maximum      
value of measured level
1...4095
Output range of readings corresponding to the minimum      
value of measured level
0...4094

Omnicomm LLS 4

With unprecedented accuracy and reliability, this sensor is extremely tough, with increased all-round protection, including against humidity and electrostatic, electromagnetic and conducted interference. The sensor head is specially designed to improve shock resistance while its compact size facilitates installation even in units very close to the fuel tank.


Omnicomm LLS 4
Error in measurement, % ± 1,0 
Output RS-232, RS-485
Power supply voltage, V 7...80 
Ingress protection rating IP69k
Dielectric strength of galvanic isolation, min, V 1500
Operating temperature, C  - 60 ... +85
Temperature measuring range, C - 40 ... + 80
Resolution, bit 12
Output range of readings corresponding to the maximum      
value of measured level
1...4095
Output range of readings corresponding to the minimum      
value of measured level
0...1023

Omnicomm LLS-AF 4

Used with terminals that don’t yet support connection of the LLS 4 digital sensor, this sensor has analog and frequency-modulated outputs protected by galvanic insulation and working independently throughout the range of power supply voltage. A special ‘Tough Road Conditions mode’ provides extra smoothing with several levels of filtration algorithms for consistent high performance in extreme road conditions.


Omnicomm LLS-AF 4
Error in measurement, % ± 1,0 
Output RS-232, RS-485
Power supply voltage, V 7...80 
Ingress protection rating IP69k
Dielectric strength of galvanic isolation, min, V 1500
Operating temperature, C  - 60 ... +85
Temperature measuring range, C - 40 ... + 80
Resolution, bit 12
Output range of readings corresponding to the maximum      
value of measured level
1...4095
Output range of readings corresponding to the minimum      
value of measured level
0...1023

Helping businesses save fuel and money since 1998

30% REDUCTION IN FUEL COSTS
SMART TRACKER
Mexican fleet management service provider SMART TRACKER integrated OMNICOMM fuel-level sensors with their system. Saved $50,000 per month & cut fuel costs by 30% for just one client.
Mexican fleet management service provider SMART TRACKER integrated OMNICOMM fuel-level sensors with their system. Saved $50,000 per month & cut fuel costs by 30% for just one client.
SAVES €60,000 ANNUALLY
PZC VARAZDIN D.D.
Croatian road construction company PZC VARAZDIN D.D. uses OMNICOMM fuel-level sensors connected to fleet management system. Cut fuel costs by 20%, equivalent to €60,000 annually.
Croatian road construction company PZC VARAZDIN D.D. uses OMNICOMM fuel-level sensors connected to fleet management system. Cut fuel costs by 20%, equivalent to €60,000 annually.

Ready to save money on fuel?

Calculate potential savings today and get a personalized quote from our specialist

About OMNICOMM

  • 20+ years of experience
  • 1+ million vehicles equipped with our fuel-level sensors
  • 110 countries where OMNICOMM products are sold
  • 3,000+ partners serving satisfied customers worldwide

Interested in finding out more? Get in touch

Please enter your name.
Please enter company name.
Please enter valid email.
Please enter valid phone.
Fields marked with * are required.